Location: Michigan
Scale Pit Repairs - Michigan Terminal
Project Description
- Repair to concrete perimeter wall of 2 scale pits in high traffic areas
- Weld repairs to angles while using confined space entry safety measures
- Concrete repairs utilizing 8000 PSI rapid set site mix
- Innovative jacking and cribbing method was utilized to lift and lower scales
- Silica monitoring and documentation was completed during the project